_ASSAY_METADATA.TXT
Version 1

_p_SUSPHIRE/_I_T21_SXPsysbio/_S_P1_SxPAltAcTransferases/_A_SxPAlternativeAcetyltransferases-GCMS/

SEEK ID: https://fairdomhub.org/data_files/5037?version=1

Filename: _ASSAY_METADATA.TXT  Download

Format: Plain text document

Size: 3.33 KB

Assay:	_A_SxPAlternativeAcetyltransferases-GCMS
Short Name:	SxPAlternativeAcetyltransferases-GCMS
Assay Class:	WET
Assay Type:	GCMS
Title:	Assay of transient expression of alternative acetyltransferases
Description:	The purpose of this assay is to test the efficiency of conversion of Z11-16OH to Z11-16OAc, in the search of a more efficient alternative to the already used EaDact acetyltransferase gene, chosen for the generation of the SxPv10 and SxPv12. The expression is assayed in a transient expression assay on WT Nicotiana benthamiana plants, agroinfiltrated with the combination of the two previous genes required in the metabolic pathway of moth sex pheromones plus the assayed acetyltransferase gene. Samples were finally measured by GC-MS.
pISA Assay creation date:	2021-11-25
pISA Assay creator:	RMF
Lab manager:	DO
Sample collection protocol:	Between 5 and 6 disks were collected 5 days postinfiltration using a 1.5-2 cm corkborer and snap frozen in liquid nitrogen.
Extraction protocol:	50mg of frozen, ground leaf samples were weighed in a 10mL headspace screw-cap vial and stabilized by adding 1mL of 5M CaCl2 and 150 ‘L of 500mM EDTA (pH = 7.5), after which they were sonicated for 5 minutes. Volatile compounds were captured by means of headspace solid phase microextraction (HS-SPME) with a 65 ‘m polydimethylsiloxane/divinylbenzene (PDMS/DVB) SPME fiber (Supelco, Bellefonte, PA, USA). Volatile extraction was performed automatically by means of a CombiPAL autosampler (CTC Analytics). Vials were first incubated at 80›C for 3 minutes with 500 rpm agitation. The fiber was then exposed to the headspace of the vial for 20 min under the same conditions of temperature and agitation. Desorption was performed at 250›C for 1 minute (splitless mode) in the injection port of a 6890N gas chromatograph coupled to a 5975B mass spectrometer (Agilent Technologies). After desorption, the fiber was cleaned in a SPME fiber conditioning station (CTC Analytics) at 250›C for 5 min under a helium flow.
Chromatography protocol:	Chromatography was performed on a DB5ms (60 m, 0.25 mm, 1 ‘m) capillary column (JandW) with helium as the carrier gas at a constant flow of 1.2mLxmin-1. The oven conditions started with an initial temperature of 160›C for 2 min, 7›Cmin-1 ramp until 280›C, and a final hold at 280›C for 6 minutes.
Mass spectrometry protocol:	Electron impact ionization (EI), 70 eV ionization energy, MS source temperature 230õC, MS quadrupole temperature 150õC, single quadrupole detector, m/z range 35-300.
Phenodata:	../../phenodata_20200723.txt
Featuredata:	
Creation date:	2020-07-23
Extract ID:	$_extr
Extraction Method:	HS-SPME
Date Extraction:	2020-07-23
Derivatization or Labelling:	none
Date Derivatization or Labelling:	2020-07-23
Derivatized or labeled Extract ID:	$_extrD
Other Post Extraction Procedures:	
Storage:	
Date GC-MS Run:	2020-07-23
GC Instrument:	6890N gas chromatograph (Agilent Technologies)
GC Autosampler Model:	CombiPAL autosampler (CTC Analytics)
GC Column model:	DB5ms (60m, 0.25 mm, 1um) capillary column (JandW)
GC Column type:	capillary column
Guard Column:	
MS Scan polarity:	positive
MS Scan mz range:	35-300
MS Instrument:	5975B mass spectrometer (Agilent Technologies)
MS Ion source:	electron ionization (EI)
Mass analyzer:	quadrupole mass filter
Operator:	RMF
Notes:	
Data:	https://doi.org/10.5281/zenodo.5810507
help Creators and Submitter
Creator
Submitter
Activity

Views: 1112   Downloads: 33

Created: 9th Apr 2022 at 18:44

Last updated: 21st Sep 2022 at 10:45

help Attributions

None

Version History

Version 1 (earliest) Created 9th Apr 2022 at 18:44 by Marko Petek

No revision comments