_p_SUSPHIRE/_I_T21_SXPsysbio/_S_P1_SxPv10vsSxP12/_A_LeavesSxPv10vsv12-GCMS/
Assay: _A_LeavesSxPv10vsv12-GCMS Short Name: LeavesSxPv10vsv12-GCMS Assay Class: WET Assay Type: GCMS Title: Leaf volatilome of SxPv1.0, SxPv1.2 T1 and WT Description: The purpose of this assay is to define the volatilome of SxPv1.0, v1.2 and WT Nicotiana benthamiana plant leaves, focusing on the differences between them, by GC-MS. pISA Assay creation date: 2020-12-12 pISA Assay creator: RMF Lab manager: DO Sample collection protocol: Leaf samples were collected at 4 weeks after transplant for young stage and at 7 weeks for adult stage (early flowering). Samples were collected between 4 and 6 pm, frozen in liquid nitrogen immediately after collection, and ground afterwards. Extraction protocol: 50mg of frozen, ground leaf samples were weighed in a 10mL headspace screw-cap vial and stabilized by adding 1mL of 5M CaCl2 and 150 æL of 500mM EDTA (pH = 7.5), after which they were sonicated for 5 minutes. Volatile compounds were captured by means of headspace solid phase microextraction (HS-SPME) with a 65 æm polydimethylsiloxane/divinylbenzene (PDMS/DVB) SPME fiber (Supelco, Bellefonte, PA, USA). Volatile extraction was performed automatically by means of a CombiPAL autosampler (CTC Analytics). Vials were first incubated at 80øC for 3 minutes with 500 rpm agitation. The fiber was then exposed to the headspace of the vial for 20 min under the same conditions of temperature and agitation. Desorption was performed at 250øC for 1 minute (splitless mode) in the injection port of a 6890N gas chromatograph coupled to a 5975B mass spectrometer (Agilent Technologies). After desorption, the fiber was cleaned in a SPME fiber conditioning station (CTC Analytics) at 250øC for 5 min under a helium Chromatography protocol: Chromatography was performed on a DB5ms (60 m, 0.25 mm, 1 æm) capillary column (JandW) with helium as the carrier gas at a constant flow of 1.2mLxmin-1. The oven conditions started with an initial temperature of 160øC for 2 min, 7øCmin-1 ramp until 280øC, and a final hold at 280øC for 6 minutes. Mass spectrometry protocol: Electron impact ionization (EI), 70 eV ionization energy, MS source temperature 230§C, MS quadrupole temperature 150§C, single quadrupole detector, m/z range 35-300. Phenodata: ../../phenodata_20201212.txt Featuredata: Creation date: 2020-12-12 Extract ID: $_extr Extraction Method: HS-SPME Date Extraction: 2020-12-12 Derivatization or Labelling: none Date Derivatization or Labelling: 2020-12-12 Derivatized or labeled Extract ID: $_extrD Other Post Extraction Procedures: Storage: Date GC-MS Run: 2020-12-12 GC Instrument: 6890N gas chromatograph (Agilent Technologies) GC Autosampler Model: CombiPAL autosampler (CTC Analytics) GC Column model: DB5ms (60m, 0.25 mm, 1um) capillary column (JandW) GC Column type: capillary column Guard Column: MS Scan polarity: positive MS Scan mz range: 35-300 MS Instrument: 5975B mass spectrometer (Agilent Technologies) MS Ion source: electron ionization (EI) Mass analyzer: quadrupole mass filter Operator: RMF Notes: Data: https://doi.org/10.5281/zenodo.5810521
Creators and SubmitterCreator
Submitter
Activity
Views: 978 Downloads: 20
Created: 9th Apr 2022 at 18:44
Last updated: 21st Sep 2022 at 10:45
AttributionsNone
Version History
Version 1 (earliest) Created 9th Apr 2022 at 18:44 by Marko Petek
No revision comments
Download
View content
https://orcid.org/0000-0003-3644-7827