#Item name GC-MS-EAD runs to test biological activity of plant produced pheromone Creation date 20-Nov-21 #Extraction Extract ID SxPv1-2 Extract Name SxPv1-2 fractions Extraction Method Solvent extraction with 40 mL toluene (per 10g leaves) with magnetic agitation for 12h. Plant material previously grounded with sand. Date Extraction #Post Extraction Derivatization or Labelling none Date Derivatization or Labelling none Derivatized or labeled Extract ID none Derivatized or labeled Extract Name none Other Post Extraction Procedures fractionation of the extract in a gravity column using silical gel as stationary phase and hexane-eter as solvent. Selection of fractions containing biosynthetic Z11C16OL for EAG. Storage direct analysis #Chromatography Date GC-MS Run GC Instrument Clarus 600 GC/MS GC Autosampler Model Clarus 600 GC/MS GC Column model Zebron ZB5-MS GC Column type fused silica capillary column 30mx0.25x0.25 Guard Column none #Mass spectrometry MS Scan polarity positive MS Scan mz range 40-500 MS Instrument Clarus 600 MS MS Ion source electron ionization (EI) Mass analyzer simple quadrupole Raw Spectral Data Files Blank #Electroantennography Instrument Syntech CS-55 stimulus controller Air flow 50 mlmin Stimuli deliverer GC stream #Other Operator Sandra Vacas Notes